2017 Crc Floor Joist

For other grades and species and for other loading conditions refer to the awc stjr.
2017 crc floor joist. Panel or stucco shear panel. Section 91 2308 8 3 joists 91 2308 10 4 3 rafters b when the span of the header around openings exceeds 4 feet the trimmer and header joists or rafters shall be doubled or lumber of equivalent cross section shall be used. The building america field kit allows you to save. Cut pieces of unfaced rigid foam sheathing to fit along the band joist in each floor joist cavity.
Step 1 check the code. The header joists or rafters shall be supported by framing. Use pieces of rigid foam that are cut to fit and sealed in place with canned spray foam to insulate the band joist above a crawlspace. T handouts plans attachments 2006 irc ibc 06 notching boring doc plan attachment notching and boring ibc section 2308 irc r502 8 r802 7 2 joists studs rafters and beams notching should be avoided when possible and holes bored in beams and joists create the same problems as notches.
For this example i ll use the icc which serves as the model for many state and local codes. First check the local code for allowable live load dead load and deflection see figure 2. Floor joist spans for common lumber species residential living areas live load 40 psf l 360 dead load 10 psf dead load 20 psf 2x6 2x8 2x10 2x12 2x6 2x8 2x10 2x12 maximum floor joist spans joist spacing inches. Joists have at least 18 clearance to exposed ground and girders have at least 12 clearance.
Table r502 3 1 1 shall be used to determine the maximum allowable span of floor joists that support sleeping areas and attics that are accessed by means of a fixed stairway in accordance with section r311 7 provided that the design live load does not exceed 30 pounds per square foot 1 44 kpa and the design dead load does not exceed 20 pounds per square foot 0 96 kpa. When sizing joists use the clear span the length from support to support not the full length of the joist. Slab on grade construction where stucco is applied over sheathing provide 2 layers grade d paper under lath n 2x4 stud wall 16 oc df stud grade minimum r 13 10 batt rigid insul 15 32 wood str. Where the header joist span is than 4 trimmer joists and the header joist shall be doubled.
Ceiling joists to plate toenail 3 8d continous header to stud toenail 4 8d ceiling joists laps over partitions face nail 3 16d min see table 2308 10 4 1 ceiling joists to parallel rafters face nail 3 16d rafter to plate face nail 3 8d built up corner studs 16d 24 oc roof rafter 2x ridge beam 2 16d toenail face nail 2 planks 16d at. 2x ceiling joists 2x solid blocking w approved framing anchor ea. Spans for ceiling joists shall be in accordance with tables r802 4 1 and r802 4 2.